Mobile navigation
Fan Selection Software
Operating point
Select fan type
HPB-F 105/110Hz - Centrifugal fan

HPB-F 105/110Hz

Centrifugal fan

High-pressure centrifugal fans with direct drive. Riveted impeller made of aluminum sheet, with B-type blades. REQUIRED USE OF THE FREQUENCY DRIVE
Can be painted in a color
other than standard
Contact us

APPLICATION

The fan is designed for transport systems of non-aggressive and non-explosive gases without impurities. Typical applications are:
  • pneumatic conveying,
  • blowing in drying systems (e.g. graphic machines and plastics processing,
  • Air supply systems for combustion/heat treatment (e.g. melting furnaces).

CONSTRUCTION

  • High pressure centrifugal fan with direct drive,
  • riveted impeller made of aluminium sheet, with type B blades, dynamically balanced to ISO 1940-1,
  • cast aluminium housing,
  • base welded from steel sheet,
  • fan painted in grey RAL7042 (motor in manufacturer's color)
  • maximum temperature of pumped medium 80°C,
  • motor ambient temperature from -20°C to +40°C,
  • standard shape LG270.

MOTOR

  • asynchronous, three phase, 230/400V, 105/110Hz or 400V, 110Hz (depending on motor power),
  • insulation class F,
  • protection degree IP55,
  • equipped with thermal protection PTC,
  • frequency converter required for proper fan operation,
  • equipped with one EMC gland = power supply, + one M16 gland for PTC sensor

SPECIAL EXECUTIONS

  • optional configuration LG / RD figure
  • painted in a color other than the standard one,
  • Impeller made of galvanized steel sheet,
  • Impeller made of stainless steel sheet 1.4301,
  • impeller made of stainless steel sheet 1.4404,
  • motor with a different IP degree of protection,
  • motor with sensors or additional cooling.

MOTOR TRANSDUCER

The converter supplying the motor must have the following classification U (f):
where: U - rated voltage of the motor operation; f - frequency 105/110Hz

If the recommendations are not followed, the motor current increases disproportionately and the drive motor does not reach the rated speed. Under no circumstances should the frequency (rotational speed) be set higher than the 100Hz frequency stated on the nameplate, because the motor may be overloaded or the fan damaged due to too high speed. The so-called boost, as this causes the drive motor to heat up too much. In order to protect the drive motor, a temperature sensor must be connected to the corresponding inputs of the converter.

Technical assistance

Choose a fan www.fanselectoronline.com

m3/h
Pa

Work characteristics

Dimensions

Type A B C E F S T X Y
  mm mm mm mm mm mm mm mm mm
HPB-F-020-075T 327 333 280 160 174 59 62 4 19
HPB-F-020-110T 327 333 321 160 174 59 62 4 19
HPB-F-025-110T 327 333 321 160 174 59 62 4 19
HPB-F-025-150T 327 333 321 160 174 59 62 4 19
HPB-F-030-110T 357 370 309 180 208 93 43 4 20
HPB-F-030-150T 357 370 330 180 208 93 43 4 20
Type Z N1 N2 N3 N4 P1 P2 X1
  mm mm mm mm mm mm mm mm
HPB-F-020-075T 14 29,5 107 158 180 80 120 4
HPB-F-020-110T 14 29,5 107 158 180 80 120 4
HPB-F-025-110T 14 29,5 107 158 180 80 120 4
HPB-F-025-150T 14 29,5 107 158 180 80 120 4
HPB-F-030-110T 12 20 116 158 190 80 120 4
HPB-F-030-150T 12 20 116 170 190 80 120 4
Type ØO ØD1 ØD2 ØD3 ØO1 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm mm
HPB-F-020-075T 10 165 139 126 M8 115 95 65
HPB-F-020-110T 10 165 139 126 M8 115 95 65
HPB-F-025-110T 10 165 139 126 M8 115 95 65
HPB-F-025-150T 10 165 139 126 M8 115 95 65
HPB-F-030-110T 11 165 139 126 7 160 135 100
HPB-F-030-150T 11 165 139 126 7 160 135 100
Type A B C E F S T X Y
  mm mm mm mm mm mm mm mm mm
HPB-F-040-220T 405 444 362 200 245 85 60 4 20
HPB-F-040-xxxT 405 444 362 200 245 85 60 4 20
HPB-F-040-300T 405 444 380 200 245 85 60 4 20
Type Z N1 N2 N3 N4 P1 P2 X1
  mm mm mm mm mm mm mm mm
HPB-F-040-220T 12 20 127 170 190 80 120 4
HPB-F-040-xxxT 12 20 127 170 190 80 120 4
HPB-F-040-300T 12 20 127 170 190 80 120 4
Type ØO ØD1 ØD2 ØD3 ØO1 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm mm
HPB-F-040-220T 10 200 165 150 17 165 139 100
HPB-F-040-xxxT 10 200 165 150 17 165 139 100
HPB-F-040-300T 10 200 165 150 17 165 139 100
Type A B C E F S T X Y
  mm mm mm mm mm mm mm mm mm
HPB-F-200-300T 450 514 358 210 290 91 59 4 13
HPB-F-200-400T 450 514 - 210 290 91 59 4 13
HPB-F-260-400T 450 514 380 210 290 91 59 4 13
HPB-F-260-550T 450 514 492 210 290 91 59 4 13
HPB-F-260-750T 450 514 492 210 290 91 59 4 13
Type Z N1 N2 N3 N4 P1 P2 X1
  mm mm mm mm mm mm mm mm
HPB-F-200-300T 13 18 218 328 350 200 250 4
HPB-F-200-400T 13 18 218 328 350 200 250 4
HPB-F-260-400T 13 18 218 328 350 200 250 4
HPB-F-260-550T 13 18 218 328 350 200 250 4
HPB-F-260-750T 13 18 218 328 350 200 250 4
Type ØO ØD1 ØD2 ØD3 ØO1 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm mm
HPB-F-200-300T 10 165 139 126 17 165 139 100
HPB-F-200-400T 10 165 139 126 17 165 139 100
HPB-F-260-400T 10 200 182 162 17 165 139 100
HPB-F-260-550T 10 200 182 162 17 165 139 100
HPB-F-260-750T 10 200 182 162 17 165 139 100
Type A B C E F S T X Y
  mm mm mm mm mm mm mm mm mm
HPB-F-200A-270T 451 507 380 210 282 83 59 4
Type Z N1 N2 N3 N4 N5 N6 P1 P2
  mm mm mm mm mm mm mm mm mm
HPB-F-200A-270T
Type X1 ØO ØD1 ØD2 ØD3 ØO1 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm mm mm
HPB-F-200A-270T 4 9.5 165 139 126 M8 165 139 100
Type A B C E F S T X Y Z
  mm mm mm mm mm mm mm mm mm mm
HPB-F-300-750T 523 624 516 248 367 145 73 4 28 12
HPB-F-300-1100T 523 624 685 248 387 165 73 4 28 12
HPB-F-300-1500T 523 624 685 248 387 165 73 4 28 12
Type N1 N2 N3 N4 N5 P1 P2 X1
  mm mm mm mm mm mm mm mm
HPB-F-300-750T 31 221 396 411 470 340 380 8
HPB-F-300-1100T 31 221 396 411 470 340 380 8
HPB-F-300-1500T 31 221 396 411 470 340 380 8
Type ØO ØD1 ØD2 ØD3 ØO1 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm mm
HPB-F-300-750T 10 200 182 140 5 191 165 125
HPB-F-300-1100T 10 200 182 140 5 191 165 125
HPB-F-300-1500T 10 200 182 140 5 191 165 125
Type A B C E F S T X N1
  mm mm mm mm mm mm mm mm mm
HPB-F-360-1500T 570 649 692 270 368 135 86 4 50
HPB-F-360-1850T 570 649 692 270 368 135 86 4 50
Type N2 N3 N4 N5 N6 N7 N8
  mm mm mm mm mm mm mm
HPB-F-360-1500T 240 377 395 415 463 56 234
HPB-F-360-1850T 240 377 395 415 463 56 234
Type P1 P2 P3 X1 X2 ØO ØD1
  mm mm mm mm mm mm mm
HPB-F-360-1500T 334 390 430 4 10 10 200
HPB-F-360-1850T 334 390 430 4 10 10 200
Type ØD2 ØD3 ØO1 ØO2 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm
HPB-F-360-1500T 182 162 7 15 230 200 160
HPB-F-360-1850T 182 162 7 15 230 200 160
Type A B C E F S T X
  mm mm mm mm mm mm mm mm
HPB-F-400-1850T 625 700 779 295 400 125 88 8
HPB-F-400-2200T 625 700 779 295 400 125 88 8
Type N1 N2 N3 N4 N5 N6 N7
  mm mm mm mm mm mm mm
HPB-F-400-1850T 35 262 495 516 530 166 356
HPB-F-400-2200T 35 262 495 516 530 166 356
Type P1 P2 P3 X1 X2 ØO ØD1
  mm mm mm mm mm mm mm
HPB-F-400-1850T 390 410 458 8 10 12 234
HPB-F-400-2200T 390 410 458 8 10 12 234
Type ØD2 ØD3 ØO1 ØO2 Ød1 Ød2 Ød3
  mm mm mm mm mm mm mm
HPB-F-400-1850T 200 162 5 13 234 200 160
HPB-F-400-2200T 200 162 5 13 234 200 160

Additional equipment


Venture Industries Group